1. Introduction

1.1 General

The following instructions provide guidance for the installer and end-user of Thermino® ePlus and xPlus Heat Batteries when used with compatible solar/PV power diverters.

These instructions must be read in conjunction with the Installation and User Instructions Manual for the Thermino ePlus (document D0083) and xPlus (document D0084) products.

WARNING

All installations must be carried out by a competent installer in accordance with local codes and regulations for plumbing, electrical installations and potable water supply.

1.2 Symbols Used

In these instructions the following symbols are being used to draw the user’s attention to information of particular importance.

WARNING

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

CAUTION

Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury or material damage.

NOTICE

Signals information that is considered important but not hazard related.

1.3 Abbreviations

The following abbreviations are used throughout these instructions:

  • PV - Photovoltaics

  • PDC – Power Diversion Controller

  • NTC - Negative Temperature Coefficient


2. Safety

2.1 General Safety Notices

WARNING

Only competent persons suitably qualified to carry out plumbing and electrical work may undertake installations, repairs or relocations of the appliance.
Product training on the full range of Thermino heat batteries is available from Sunamp or authorised training partners.

WARNING

Risk of electric shock – potential dual supply. Always isolate the power supplies to the heat battery controller before working on the heat battery.

CAUTION

These instructions must be read in conjunction with the Installation and User Instructions for the respective Thermino product.

CAUTION

Do not operate the immersion heater until the correct commissioning procedure has been identified and the unit has been appropriately commissioned (see document D0114).


4S - 4 Noks Power Reducer SA

WARNING 

All Electrical wiring must be carried out by a competent person and be in accordance with the latest local wiring codes and regulations. 
Risk of electric shock – potential dual-supply. Always isolate the power supply/ies to the Heat Battery, Heat Pump & Solar Diverter controller (if used) before working on the appliances. 

These settings are applicable to the following products:

  • Thermino ePlus with PV02 Optimino key (document D0083 – Section 6.4.2 for wiring instructions & Figure 1 below)

  • Thermino xPlus with any “02” Optimino key (document D0084 – Section 6.4.2 for wiring instructions & Figure 1 below)

  • Solar Power Diversion Controllers from the 4-Noks Power Reducer SA range

4S.1 - Wiring setup: 4 Noks Power Reducer SA & Thermino ePlus/xPlus

Figure 4S.1 - 4 Noks Power Reducer SA wiring instructions


4S.2 - Settings to be applied to the 4 Noks Power Reducer SA

4S.2.1 - Applying a manual grid boost

A Manual Boost on absence of Solar load can be applied to the Thermino Heat Battery by wiring a Volt-Free Switch into the terminals “+10V” and “CTRL”, and closing the circuit as detailed in Figure 4S.2 below. Please note that to allow the device to revert to Solar Load only, the switch needs to be deactivated. The switch MUST NOT be a fused spur and needs to be Volt-Free.

Figure 4S.1 - Wiring of Grid Boost Switch on absence of Solar Load

NOTICE

For any additional wiring or settings instructions, please refer to the solar power diversion controller manufacturer's installation and user manual.



Document Part Number: D0085-4S

Version Number: 1.1

Publication Date: 03.06.2024

Sunamp Ltd

1 Satellite Park

Macmerry

East Lothian

EH33 1RY

Scotland


Customer Service (Phone): +44 (0)1875 610 001