1. Introduction

1.1 General

The following instructions provide guidance for the installer and end-user of Thermino® ePlus and xPlus Heat Batteries when used with compatible solar/PV power diverters.

These instructions must be read in conjunction with the Installation and User Instructions Manual for the Thermino ePlus (document D0083) and xPlus (document D0084) products.

1.2 Symbols Used

In these instructions the following symbols are being used to draw the user’s attention to information of particular importance.

WARNING

Indicates a hazardous situation that, if not avoided, could result in death or serious injury.

CAUTION

Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury or material damage.

NOTICE

Signals information that is considered important but not hazard related.

1.3 Abbreviations

The following abbreviations are used throughout these instructions:

  • PV - Photovoltaics

  • PDC – Power Diversion Controller

  • NTC - Negative Temperature Coefficient


2. Safety

2.1 General Safety Notices

WARNING

Only competent persons suitably qualified to carry out plumbing and electrical work may undertake installations, repairs or relocations of the appliance.
Product training on the full range of Thermino heat batteries is available from Sunamp or authorised training partners.

WARNING

Risk of electric shock – potential dual supply. Always isolate the power supplies to the heat battery controller before working on the heat battery.

CAUTION

These instructions must be read in conjunction with the Installation and User Instructions for the respective Thermino product.

CAUTION

Do not operate the immersion heater until the correct commissioning procedure has been identified and the unit has been appropriately commissioned (see document D0114).


MA - Mia Energy Series Kit power diversion controller

WARNING 

All Electrical wiring must be carried out by a competent person and be in accordance with the latest local wiring codes and regulations. 
Risk of electric shock – potential dual-supply. Always isolate the power supply/ies to the Heat Battery, Heat Pump & Solar Diverter controller (if used) before working on the appliances. 

These settings are applicable to the following products:

  • Thermino ePlus with PV02 Optimino key (document D0083 – Section 6.4.2 for wiring instructions & Figure 1 below)

  • Thermino xPlus with any “02” Optimino key (document D0084 – Section 6.4.2 for wiring instructions & Figure 1 below)

  • Solar Power Diversion Controllers from the Mia Energy Series Kit range

MA.1 - Wiring setup: Mia Energy Series Kit & Thermino ePlus/xPlus


Figure MA.1 - Mia Energy Series Kit wiring instructions


MA.2 - Settings to be applied to Mia Energy Series Kit PDC

NOTICE

For configuration of applicable settings on the MIA Energy power diversion controller, please refer to the manufacturer’s user and installation instructions.

NOTICE

Please refer to the solar power diversion controller manufacturer's installation and user manual for detailed wiring and settings instructions.