Technical Note: Thermino input data for SAP10.2
(D0089)
NOTICE
Please note the information in this document is for guidance only and may be used to help you model and assess the energy performance of dwellings when Sunamp heat batteries are installed in homes. Whilst every effort is made to ensure the information is accurate, the information is provided as is and without warranty. Energy performance results depend on the correct input of data and the outputs from different SAP-approved software models.
1. Introduction
1.1 General
The thermal performance and the functional categorisation of hot water heating products affects the Energy and the Environmental efficiencies and ratings of domestic dwellings carried out using SAP10.2. This technical note covers the SAP10.2 input parameters required for the 5th Generation Sunamp Thermino products for SAP assessments.
The following tables provide guidance for relevant input data for planners, specifiers, installers and end-users of Thermino® ePlus and xPlus heat batteries. This data is to be used in version 10.2 of the Standard Assessment Procedure (SAP) for energy performance modelling of a dwelling. The relevant SAP10.2 documentation and worksheet can be found here: https://bregroup.com/expertise/energy/sap/sap10
1.2 Symbols Used
In these instructions the following symbols are being used to draw the user’s attention to information of particular importance.
WARNING
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury or material damage.
NOTICE
Signals information that is considered important but not hazard related.
1.3 Abbreviations
The following abbreviations are used throughout the document:
PV - Photovoltaics
SAP - Standard Assessment Procedure
2. Thermino ePlus & xPlus data fro SAP10.2
2.1 Thermino ePlus input data
Thermino ePlus models provide hot water heating only (via the integrated heating element) using direct grid electricity (no Optimino key required), or direct grid electricity and solar PV via diversion controller (only if Optimino PV02 key is used).
NOTICE
Equivalent conventional products: Direct hot water cylinders, direct hot water only thermal stores (electric).
Parameter |
Unit |
Thermino |
Thermino 150 ePlus |
Thermino 210 ePlus |
Thermino 300 ePlus |
SAP10.2 worksheet Ref. No. |
Equivalent Hot Water Cylinder Size (1) |
L |
74 |
140 |
212 |
306 |
[47] |
Standby Heat loss rate |
kWh/24h |
0.48 / (20) |
0.67 / (28.1) |
0.77 / (32.1) |
0.84 / (34.9) |
[48] |
High-rate fraction for electric DHW heating (when using E7/E10 tariffs) |
use values from “dual” data columns
|
[243], Tables 12,13 |
||||
Table 1 - Thermino ePlus input data for SAP10.2
2.2 Thermino xPlus input data
Thermino xPlus models provide hot water heating with an optional backup direct electric heating element. Thermino xPlus offers the flexibility of multiple input heat source options including:
external heat pump as primary heat source (requires Optimino hp key)
external heat pump AND solar PV as primary heat sources (requires Optimino hpPV Key)
external boiler as primary heat source (requires Optimino vf Key)
external boiler AND solar PV as primary heat sources (requires Optimino vfPV Key)
NOTICE
Equivalent conventional products: Indirect hot water cylinders, indirect hot water only thermal stores.
Parameter |
Unit |
Thermino 150 xPlus |
Thermino 210 xPlus |
Thermino 300 xPlus |
SAP10.2 worksheet Ref. No. |
Equivalent Hot Water Cylinder Size (1) |
L |
142 |
212 |
284 |
[47] |
Equivalent Hot Water Cylinder Size (2) |
L |
128 |
192 |
256 |
[47] |
Standby Heat loss rate |
kWh/24h |
0.67 / (28.1) |
0.77 / (32.1) |
0.84 / (34.9) |
[48] |
Heat Transfer Area |
m2 |
2.10 |
3.10 |
3.60 |
- |
High-rate fraction for electric DHW heating (when using E7/E10 tariffs) |
use values from “dual” data columns
|
[243], Tables 12,13 |
|||
Table 2 - Thermino xPlus input data for SAP10.2
NOTICE
Table 1 & 2 notes:
1. Calculated from the storage capacity of the Heat Battery and assuming that the equivalent hot water cylinder thermostat is set at 60°C, mains cold water inlet temperature is at 10°C and the stored energy utilisation factor of the cylinder is 0.85.
2. Calculated from the storage capacity of the Heat Battery when charged to heat pump set points and assuming that the equivalent hot water cylinder thermostat is set at 60°C, mains cold water inlet temperature is at 10°C and the stored energy utilisation factor of the cylinder is 0.85
2.3 Adding PV diversion
If using Thermino ePlus or xPlus heat batteries with solar PV functionality (using the appropriate Optimino PV key), then please follow Appendix G4 for treatment of PV diverters, and Appendix M1 for treatment of Photovoltaics. The calculation and associated cost-savings methods can be found in the SAP10.2 documentation: https://bregroup.com/expertise/energy/sap/sap10
2.4 Adding heat pumps
When using heat pumps with Thermino xPlus models (by using the appropriate Optimino hp or hpPV key), relevant input heat pump data can be accessed from the Product Characteristic Database (PCBD). The PCDB can be accessed here: Building Energy Performance Assessment - Support Website : Search (ncm-pcdb.org.uk)
NOTICE
For a full list of available Optimino keys and compatible heat pumps & solar power diverters, please visit our website here: https://sunamp.com/optimino-resources-for-installers/
Document Part Number: D0089
Version Number: 1.1
Publication Date: 09.02.24